Data Acquisition
|
Thermocouple Temperature Measurement InstrumentsSupports most thermocouple types, automatic CJC and linearization
Product Highlights Product Highlights
DATAQ Instruments' DI-1000TC Series products are a line of instrumentation modules designed for temperature measurements using thermocouples. The unit is provided in 4- or 8-channel versions, and each channel may be configured in software to support one of seven thermocouple types: J, K, T, E, S, B, or R. Temperature measurements may range from -200°C to +1820°C (-328°F to +3308°F), depending upon thermocouple type. Each DI-1000TC thermocouple channel features a panel-mounted, miniature spade connector, and all input channels are electrically isolated from ground and each other up to 1000VDC, or peak AC. Model DI-1000TC is designed for use across the entire spectrum of temperature measurement applications that use thermocouples. Its small size and wide measurement range make it a perfect temperature measurement device for laboratory applications. Its isolation feature allows it to be used in more demanding industrial applications that experience the large common mode voltages (off-ground measurements) that are typical of grounded thermocouples. Such measurement situations will prevent non-isolated instruments from making a measurement at best, or destroy them in the worst case. See our page on how to make safe and accurate thermocouple measurements using isolated instrumentation by clicking here. ExpandableMultiple DI-1000TC units may be connected individually, or used as expansion units with any combination of other DI-1000 instruments to address any application-specific temperature measurement situation. For example, multiple DI-1000TCs may be connected to each other to provide unique 12, 16, 20, or other thermocouple channel counts. Built-in RS-422 InterfaceThe built-in RS-422 interface allows DI-1000TC units to connect to any host PC through an inexpensive adapter via an RS-232 or USB port. This interface also serves as an expansion port for other DI-1000 Series instruments (not yet released). IsolationThe DI-1000TC's 1000VDC and Peak AC input-to-output and channel-to-channel isolation allows grounded thermocouple measurements. High Accuracy and Resolution DesignAllows sharpened decisions with an overall accuracy of ±0.2%, and temperature resolution as fine as 0.08°C. PortableThe DI-1000TC is provided in a small (13.81D × 10.48W × 3.81H centimeters; 5-7/16D × 4-1/8W × 1-1/2H inches) enclosure consisting of an aluminum base and all-steel wraparound. Primary CustomersThose who need a PC-based thermocouple temperature measurement instrument for laboratory or classroom use. Examples include physics, chemistry, biology, and any other discipline that requires accurate and ready-to-run temperature measurements. Those who require a rugged and flexible device for temperature measurements using thermocouples in industrial settings where off-ground measurements are common. Specific applications are temperature measurements in:
Includes WinDaq SoftwareBe up and running minutes out of the box with WinDaq acquisition and playback software. WinDaq/Lite software is included free with the purchase of every DI-1000TC instrument. WinDaq/Lite operates at a maximum throughput recording rate of 240 Hz with a DI-1000TC Instrument. WinDaq Waveform Browser, our playback and analysis software for Windows, is distributed free with WinDaq/Lite. It is also available for download free-of-charge from this Web site. Use it to review, measure, compare, and analyze the waveform file after it has been recorded by WinDaq acquisition software. WinDaq software products support up to 14 bits of measurement resolution. WinDaq uses the NIST ITS-90 Thermocouple Database for thermocouple linearization. Ordering Information, Models, and Prices*Note: In order to connect a DI-1000TC to your PC, you MUST purchase an adapter (either DI-1000-USB, DI 1000-232F). If you are planning to daisy chain multiple devices, you only need one adapter. When ordering multiple devices, please specify whether you will be using the instruments individually or interconnected in a daisy chain. Note: Pricing outside the U.S. will be higher to account for shipping, taxes, duty, currency fluctuation, local warranty and technical support in your country. Note: This product is NOT CE approved and is not available for purchase in European Union countries. DI-1000TC Software and Accessories
Note: Pricing outside the U.S. will be higher to account for shipping, taxes, duty, currency fluctuation, local warranty and technical support in your country.
Knowledge Base and Common Support IssuesThermocouple Measurements Profile Cement Curing Characteristics of Prosthetic Implants How to Make Safe and Accurate Measurements Using Isolated Instrumentation Synchronized and Distributed Data Acquisition in Hot Strip Steel Mills Miniature Thermocouple Assembly Instructions How to Export Recorded Data to Excel Support Forum
Data Acquisition Product Links(click on text to jump to page) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||