Home > Hardware > DATAQ Starter Kit Support > Forum > DL-145 CONNECT WITH Ultrasonic Module HC-SR04

DL-145 CONNECT WITH Ultrasonic Module HC-SR04

Feb 27, 2015
nikos wrote
I want to ask if it is possible and how connect DL-145 WITH Ultrasonic Module HC-SR04
Thank you
Reply
6 Answers
Feb 27, 2015
Shawn agent wrote
Nikos,

The DI-145 has a maximum sample rate of 240 Hz.

I've forwarded your inquiry to sales for a product recommendation. 
 
Regards,
DATAQ instruments Support
Feb 27, 2015
DATAQ Support agent wrote
This ultrasonic module does not appear to have a demodulated output (a dc level proportional to distance.) It is therefore not suitable for use with the DI-145 or any other product we offer.
Mar 03, 2015
nikos wrote
product recommendation ?
Mar 04, 2015
DATAQ Support agent wrote
With an operating frequency of 40 kHz we do not have any products that are suitable for use with this sensor.
Mar 04, 2015
nikos wrote
ultrasonic module for DI-145 ?
Mar 04, 2015
DATAQ Support agent wrote
No such module exists for the DI-145. To make use of our products, or any others in our price range, requires that a demodulator be placed between the output of the sensor and the input of the data acquisition device. You should contact the sensor manufacturer for a possible solution.