EPAD2-TH8-Universal Thermocouple Temperature Data Acquisition Module
8-channel, high precision module for Thermocouple types K, J, T, R, S, N, E, C, U, or B
Stock
US orders ONLY. Please allow 1-2 week lead time. Please view our Cancellation policy BEFORE placing an order.
- Includes EPAD2-TH8-Universal, XPAD-TERM-L termination connector, XPAD-CBL-LL-2 2 meter connecting cable (substitute 0.2m, 0.5m, 5m, or 10m in order notes if required)
- Connect to PUREC data acquisition system or use the EPAD2-USB for use as a PC-connected logger with OXYGEN Software
- Amplifier with integrated 24-bit A/D conversion
- 8 isolated type Thermocouple Temperature Detector channels
- Supports Thermocouple types K, J, T, R, S, N, E, C, U, or B (specify type in order notes)
- Sensor disconnect/interruption detection
- Up to 12 samples/sec/channel, simultaneous sampling
- Accuracy dependent on Thermocouple type and measurement
- LEMO EGG.1B.304 RS-485 interface (CAN interface available - order CPAD2-TH8-Universal)







Description
The EPAD2-TH8-Universal is an 8-channel thermocouple amplifier for thermocouple types K, J, T, R, S, N, E, C, U, or B.
The EPAD2 and CPAD2 series are multichannel modules and combine analog signal conditioning and A/D converter in an extremely rugged box. All have one 24 bit A/D converter per channel, synchronized sampling, channel to channel and channel to system isolation. The sampling rate is 12 samples per second. Target applications includ precision measurement of slow signals in rough environments, e.g. in an engine bay of a vehicle, distributed monitoring of slow signals in industrial plants, high quality logging of environmental conditions.
EPAD2 and CPAD2 series modules can be daisychained to achieve a high channel count even over very long distances. Data output of CPAD2 series is available on CAN bus while EPAD2 series has a RS485 interface. Use with the PUREC data acquisition system to expand channel count or connect to a PC with OXYGEN software and the EPAD2-USB.
Accessories

Description
Mini USB interface module for attaching EPAD2 modules to USB. Includes 1.8m USB cable and external power supply (100 .. 240 V / 15 VDC) to ensure power for up to 16 daisy-chained EPAD/CPAD modules. Requires OXYGEN software licencse.

Description
Oxygen version 3.7. Supports current DEWETRON hardware. Required for the EPAD Base (i.e., running EPAD without the PUREC system). Addítional Features can be activated with a separate license and/or plugin. Includes maintenance service for 12 months.

Description
Adapter to snap EPAD2 and CPAD2 modules onto a DIN rail.

Description
SPARE termination connector for EPAD2/CPAD3 modules with Lemo EGG.1B.304 connector, the last module of the RS-485/CAN bus must be terminated with this connector. INCLUDED WITH EPAD AND CPAD MODULES.

Description
Adapter to convert EPAD interface from D-SUB-15 connector to Lemo 1B.304.

Description
Adapter cable 2 m to connect CPAD series modules to CAN interface, LEMO FGG.1B.304 plug to a D-SUB-9 socket, use only for DEWETRON systems with power supply on CAN connector.

Description
Adapter cable 2 m to connect CPAD series modules to CAN interface, LEMO FGG.1B.304 plug to a D-SUB-9 socket, additional 2 banana plugs for module power supply.

Description
EPAD2/CPAD2 connecting cable 0.2 meter Lemo FGG.1B.304 connector for daisy-chaining stacked EPAD2/CPAD2 modules.

Description
EPAD2/CPAD2 connecting cable 0.5 meter Lemo FGG.1B.304 connectors for daisy-chaining xPAD2 modules or for connecting EPAD2 series modules to a Lemo EGG.1B.304 EPAD interface.

Description
EPAD2/CPAD2 connecting cable 2 meter Lemo FGG.1B.304 connectors for daisy-chaining xPAD2 modules or for connecting EPAD2 series modules to a Lemo EGG.1B.304 EPAD interface.

Description
EPAD2/CPAD2 connecting cable 5 meter Lemo FGG.1B.304 connectors for daisy-chaining xPAD2 modules or for connecting EPAD2 series modules to a Lemo EGG.1B.304 EPAD interface.

Description
EPAD2/CPAD2 connecting cable 10 meter Lemo FGG.1B.304 connectors for daisy-chaining xPAD2 modules or for connecting EPAD2 series modules to a Lemo EGG.1B.304 EPAD interface.

Description
Adapter cable 0.1 m, converts Binder 712-series plug to Lemo 1B.304 socket. Required to connect new EPAD2 modules to old instruments with Binder 712-series EPAD interface using EPAD-CBL-LL-x cables. Required to connect EPAD modules with Binder 712-series connector to new instruments with Lemo EGG.1B.304 EPAD interface using EPAD-CBL-LL-x cables.

Description
Adapter cable 0.1 m, converts from Lemo 1B.304 plug to Binder 712-series socket. Required to connect existing EPAD modules with Binder 712-series connector to new instruments with Lemo EGG.1B.304 EPAD interface using existing EPAD-CBL-BB-x cables.

Description
Extended operating temperature range of -40°C to +85°C for EPAD2, CPAD2 and CPAD3 data acquisition modules.

Description
Calibration for NEW products ONLY. Must be ordered at time of purchase. Factory calibration reports of NEW EPAD/CPAD modules. ANSI/NCSL Z540-1 compliant. Valid for one year.
Software
OXYGEN
Data Acquisition Recording and Playback Software
All-in-one easy-to-use software for measurement, visualization, and analysis for a multitude of applications like Power Analysis, FFT, Order Analysis, and more. View and analyze data will still recording. OXYGEN-SDK plugin interface for customization. Remote control capability via TCP/IP. Unlimited installations for data view and analysis (license-free).

Specifications
Input Channels: | 8 isolated Thermocouple temperature channels | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input range: | Type K: -270 to 1372°C Type J: -210 to 1200°C) Type T: -270 to 400°C) Type R: -50 to 1760°C Type S: -50 to 1760°C Type N: -270 to 1300°C Type E: -270 to 1000°C Type L: 0 to 900°C Type C: 0 to 2300°C Type U: -200 to 600°C Type B: 0 to 1820°C |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Accuracy: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sampling rate: | max. 12.5 S/sec per channel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bandwidth (-3 dB): | 6 Hz | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ADC type: | 24 Bit Delta Sigma Converter | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input connector: | mini Thermocouple connector | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Resolution: | 0.01 °C for all types | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input impedance: | typically >1.4 MΩ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bias current: | typically 10 nA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Open Thermocouple detection: | module indicates fullscale if input is open | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max gain drift: | 25 ppm/°C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max offset drift: | 25 ppm of range /°C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Isolation voltage: | 350 VDC (channel to channel and channel to Bus, Power and Chassis) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Overvoltage protection: | 15 VDC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CMRR (50/60 Hz): | 130 dB | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Bus/Power Connector: | LEMO EGG.1B.304 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power Supply Voltage: | 7 to 40 V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption: | typically 0.5 W | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions: | Base module (W × D × H): 129 × 72 × 34.2 mm (5.1 × 2.8 × 1.3 in.) incl. mounting holes Mounting holes distance: 119 × 7 mm (4.7 × 0.3 in.), 4.2 mm (0.165 in.) diameter |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight: | typical 360g | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
EPAD2-TH8 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Interface: | RS-485 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Communication speed: | 9600 bps (2400 to 115200 programmable) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standard settings: | 9600 bps, 8 data bits, 1 stop bit, no parity, module address 00 hex | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Readout speed: | depending on baudrate and number of channels (typ. 80 ch/sec. @ 9600 bps) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CPAD2-TH8 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Interface: | highspeed CAN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Specification: | CAN 2.0B | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Communication speed: | 50 kBaud to 1000 kBaud | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Format: | 16 Bit Intel or Motorola | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Identifier Types: | standard; extended | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standard settings: | 500 kBaud; Intel Format | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Readout speed: | 12.5 Hz, 10 Hz, 5 Hz, 2 Hz, 1 Hz, 0.5 Hz, 0.2 Hz or 0.1 Hz programmable |