Site Search:

PU[REC] Pure Recording

Sixteen-channel, portable, rugged, Data Acquisition System with 15.6 inch touch screen

$11,500.00

Select Sampling Rate Option: 

In
Stock

US orders ONLY. Please allow 1-2 week lead time. Please view our Cancellation policy BEFORE placing an order.

  • Includes a PUREC mainframe with OXYGEN software pre-installed, on-board 1TB SSD, and power cable
  • 16 analog input channels using Modular Smart Signal Conditioning Inputs for specific measurements (one required for each channel):
    • 4-20mA current sensors
    • Strain-gauge sensors (quarter, half, or full bridge)
    • LVDT and RVDT sensors (5-wire)
    • IEPE (Integrated Electronics Piezo-Electric) sensors (accelerometers, force, pressure)
    • Charge sensors up to 100,000 pC
    • Thermocouple sensor types J, K, and T
    • ±20, ±50, ±100, ±200V
    • RTD sensors Pt100, Pt200, Pt500, Pt1000, Pt2000 (2, 3, or 4-wire)
  • Built-in 15.6-inch full color multi-touch display
  • Feature-rich OXYGEN Data Acquisition software included and pre-installed
    • FFT analysis
    • Visualization
    • Analysis and post-processing
    • Various Triggers and actions
    • Math and Calculated channels
    • Time and event-based file split options
    • Extensive Export Features
    • Easy Reporting
  • Built-in 1TB SSD for data storage - stores 1 week of data for 16 channels at 50,000 Samples per second
  • Review data while recording
  • Channel-specific storage options for data and statistics
  • Local operation or remote control operation
  • Multiple methods for channel expansion
    • Daisy-chain another PU[REC] device for 32 channels
    • Connect EPAD2 multichannel modules
    • Connect CPAD2 multichannel modules for CAN bus data
  • CANbus input option
  • Optional CAN output
  • Optional Ethernet Synchronization
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
PUREC Data Acquisition System
PUREC Data Acquisition System PUREC Data Acquisition System Side Panel PUREC Data Acquisition System Side Panel
This data acquisition system features 16 analog input channelsThis data acquisition system has 8 digital inputsThis data acquisition system has 4 digital outputs
This data logger features a plus/minus 10 Volt full scale range
This data logger has an Ethernet interfaceThis data logger stores data to internal memoryThis data logger can save data directly to a USB flash drive

Description

The Dewetron PU[REC] sets a new standard for portable data logging and data acquisition applications. The PU[REC] data acquisition system is portable, rugged, expandable, and easy to use. A 15.6 inch full color touch screen makes configuration and data analysis easy and intuitive. Effortlessly record and analyze data at the same time with pre-installed OXYGEN software. Varied trigger conditions with powerful trigger actions ensure you record just the data you need. Extensive math and calculation features allow you to analyze your data in real time to solve your toughest problems. Record great amounts of data with the installed 1TB solid state drive.

Each channel on the PU[REC] data acquisition system supports ±10V or an MSI (Module Smart Interface) module for specific measurements and sensors including 4-20mA current sensors, strain-gauge sensors (quarter, half, or full bridge), LVDT and RVDT sensors (5-wire), IEPE (Integrated Electronics Piezo-Electric) sensors (accelerometers, force, pressure), charge sensors (up to 100,000 pC), thermocouples (types J, K, T), voltage (up to 200V), and RTDs.

Channel expansion is possible with EPAD modules supporting 8 channels expansion with each module. Each EPAD supports a specific measurement type: Thermocouple, RTD, voltage, or 4-20mA. EPAD modules can be daisy-chained to increase channel count.

Modular Smart Interface Signal Conditioning Modules

MSI-BR-ACC

IEPE Interface

$320.00
IEPE Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for IEPE Piezo-Electric Sensors. Excitation current 4mA, 21 V. Ranges are defined by connected amplifier. Learn more.

MSI2-STG

Strain Gauge Interface

$350.00
Strain Gauge Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for strain gauge and bridge sensors. Designed to connect virtually any strain gauge to the PUREC DAQ system. Full, half, or quarter bridge. 5V or 10V excitation with remote sense. Simple connection without any soldering. 120Ω and 350Ω quarter bridge. Configuration completed via jumper. Learn more.

MSI-BR-V-200

Voltage Interface

$320.00
Voltage Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for voltage measurement ranges of ±200, ±100, ±50, and ±20 Volts. Learn more.

MSI2-250R-20mA

Current Loop Interface

$320.00
4-20mA Current Loop Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Current Loop Interface supports 4-20mA sensors. Excitation Voltage: AUX Power. Input range: ±25 mA. Push-in spring connection. Learn more.

MSI2-CH-100

Charge Interface

$320.00
Charge Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for sensors with charge output up to 100000 pC, AC coupled with 0.14 Hz, BNC signal connection, max. 70 kHz bandwidth. Learn more.

MSI2-CH-5

Charge Interface

$320.00
Charge Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for sensors with charge output up to 5000pC, AC coupled with 0.14 Hz, BNC signal connection, max. 70 kHz bandwidth. Learn more.

MSI2-LVDT

LVDT Displacement Interface

$350.00
LVDT Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for displacement with an LVDT (Linear Variable Differential Transformer). Compatible with 5 and 6-wire transducers. Provides sine wave excitation and converts sensor output into a linear voltage output. Learn more.

MSI-BR-RTD

RTD Temperature Interface

$320.00
RTD Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for RTD sensor measuring -200 to 850°C (-328 to 1562°F). Supports Resistance, Pt100, Pt200, Pt500, Pt1000, and Pt2000 RTDs. 2-, 3-, and 4-wire connections supported. Connection type is 5-pin BINDER connecttor series 712. Learn more.

MSI2-TH-J

J-Type Thermocouple Interface

$320.00
Type J thermocouple Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for J-type thermocouple temperature measurements from -210 to 1200°C (-346 to 2192°F). 1 meter thermocouple cable with mini TC connector. Automatic adapter notification. High accuracy (1°C) cold junction reference measurement. Accuracy: -100 to 1200°C: ±0.6°C; -200 to -100°C: ±1.1°C. Learn more.

MSI2-TH-K

K-Type Thermocouple Interface

$320.00
Type K thermocouple Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for K-type thermocouple temperature measurements from -200 to 1370°C (-328 to 2498°F). 1 meter thermocouple cable with mini TC connector. Automatic adapter notification. High accuracy (1°C) cold junction reference measurement. Accuracy: -100 to 1370°C: ±0.6°C; -200 to -100°C: ±1.2°C. Learn more.

MSI2-TH-T

T-Type Thermocouple Interface

$320.00
Type T thermocouple Interface for PUREC Dewetron Data Acquisition Systems

Description

Modular Smart Interface for T-type thermocouple temperature measurements from -270 to 400°C (-454 to 752°F). 1 meter thermocouple cable with mini TC connector. Automatic adapter notification. High accuracy (1°C) cold junction reference measurement. Accuracy: -100 to 400°C: ±0.8°C; -250 to -100°C: ±3°C. Learn more.

EPAD Modules

EPAD2-LA8-L1B

8-channel Process Current

$2730.00
Dewetron EPAD2-LA8-L1B 8-channel Process Current data acquisition system

Description

Dewetron EPAD2-LA8-L1B Low Current Data Acquisition Module is an 8 differential channel high precision current measurement module compatible with 4-20mA sensors. 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-RTD8-L1B

8-channel RTD Temperature

$2900.00
Dewetron EPAD2-RTD8-L1B 8-channel RTD Temperature data acquisition system

Description

Dewetron EPAD2-RTD8-L1B RTD Temperature Data Acquisition Module is an 8 differential channel high precision temperature measurement module compatible with 2- or 4-wire Pt100, Pt200, Pt500, Pt1000 and NI120 sensors. 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-TH8-J

8-channel Thermocouple Temperature

$2800.00
Dewetron EPAD2-TH8 8-channel Thermocouple Temperature data acquisition system

Description

Dewetron EPAD2-TH8-J Type-J Thermocouple Temperature Data Acquisition Module is an 8 differential channel high precision temperature measurement module compatible with J-type thermocouples measuring -210 to 1200°C (-346 to 2192°F). 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-TH8-K

8-channel Thermocouple Temperature

$2800.00
Dewetron EPAD2-TH8 8-channel Thermocouple Temperature data acquisition system

Description

Dewetron EPAD2-TH8-K Type-K Thermocouple Temperature Data Acquisition Module is an 8 differential channel high precision temperature measurement module compatible with K-type thermocouples measuring -270 to 1372°C (-454 to 2501°F). 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-TH8-T

8-channel Thermocouple Temperature

$2800.00
Dewetron EPAD2-TH8 8-channel Thermocouple Temperature data acquisition system

Description

Dewetron EPAD2-TH8-T Type-T Thermocouple Temperature Data Acquisition Module is an 8 differential channel high precision temperature measurement module compatible with T-type thermocouples measuring -270 to 400°C (-454 to 752°F). 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-TH8-Universal

8-channel Thermocouple Temperature

$3100.00
Dewetron EPAD2-TH8 8-channel Thermocouple Temperature data acquisition system

Description

Dewetron EPAD2-TH8-Universal Thermocouple Temperature Data Acquisition Module is an 8 differential channel high precision temperature measurement module compatible with types K, J, T, R, S, N, E, C, U, and B thermocouples. 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-V8-L1B

8-channel ±10 Volts

$2840.00
Dewetron EPAD2-V8-L1B 8-channel voltage data acquisition system

Description

Dewetron EPAD2-V8-L1B Voltage Data Acquisition Module is an 8 differential channel high precision voltage measurement module measuring ±100mV, ±500mV, ±1V, ±2.5V, ±5V, and ±10V. 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

EPAD2-V8

8-channel ±10 Volts

$2360.00
Dewetron EPAD2-V8 8-channel voltage data acquisition system

Description

Dewetron EPAD2-V8 Voltage Data Acquisition Module is an 8 differential channel high precision voltage measurement module measuring ±100mV, ±500mV, ±1V, ±2.5V, ±5V, and ±10V. 24-bit ADC resolution and sampling rates of 12 samples per second per channel. Connect to PU[REC] system or connect to a PC with OXYGEN software and the EPAD2-USB. Learn more.

Accessories

PUREC-BAG

Carrying Bag

$180.00
Carrying Bag for PUREC Data Acquisition System

Description

Carrying bag for PUREC data acquisition system.

CAL-PUREC-US-NEW

ISO 17025 Calibration Certificate

$500.00
Calibration Certificate

Description

Calibration for NEW products ONLY. Must be ordered at time of purchase. Factory calibration report for a PUREC System (traceable, ISO 9001:2008) includes adjustment if module has more than 70% of range tolerance. 3-4 calibration points per channel and per range.

OXYGEN Software Options for PUREC Data Acquisition System

OXY-OPT-NET

Distributed Data Acquisition Software

$2500.00
Synchronized Ethernet Data Acquisition Option for PUREC Systems

Description

OXYGEN software option for distributed data acquisition via ethernet cable. Enables multiple PUREC data acquisition systems to be used like a single unit including synchronized data acquisition, data transfer, and remote channel configuration.

PUREC-OPT-CAN

CAN Bus Option

$1500.00
CAN Bus Option for PUREC Data Acquisition Systems

Description

PUREC option for 1x highspeed CAN Interface with up to 1 MBaud

OXY-OPT-CAN-OUT

CAN Bus OUT Option

$2200.00
Ethernet Receiver Option for PUREC Data Acquisition Systems

Description

OXYGEN option for transmitting measurement data via CAN Bus. Configured with a .dbc File. Requires PUREC-OPT-CAN Option.

Ethernet Receiver

OXYGEN Ethernet Option

$2500.00
Ethernet Receiver Option for PUREC Data Acquisition Systems

Description

OXYGEN option for receiving data via ethernet, powerful decoder configured with XML-description, synchronisation via input timestamp or included timestamp (milliseconds since midnight). Only UDP packets are supported

Software

OXYGEN

Data Acquisition Recording and Playback Software

All-in-one easy-to-use software for measurement, visualization, and analysis for a multitude of applications like Power Analysis, FFT, Order Analysis, and more. View and analyze data will still recording. OXYGEN-SDK plugin interface for customization. Remote control capability via TCP/IP. Unlimited installations for data view and analysis (license-free).

OXYGEN Data Acquisition Software

Specifications

Analog Inputs
Number of Channels: 16
Sampling Rate: PUREC-50: 50,000 S/s/CH
PUREC-200: 200,000 S/s/CH
Configuration: 9-pin female D-sub, ±10V, Isolated
Auto-detected measurements per channel: Dependent on MSI signal conditioner
Programmable thermocouple types and measurement range per channel:

Over 25 ±3 °C ambient temperature range.
Stable ambient temperature.
Following 60 minutes warm-up.
Excluding common mode error.
Excluding thermocouple error.
Thermocouple Type Temperature Measurement Range (°C) Accuracy (°C)
J -190 to 1200 ±(0.1% of span + 2)
K -180 to 1360 ±(0.1% of span + 2)
T -190 to 400 ±(0.1% of span + 1)
B 600 to 1000
1001 to 1810
±(0.2% of span + 4)
±(0.1% of span + 3)
R -40 to 300
301 to 1760
±(0.2% of span + 6)
±(0.1% of span + 3)
S -40 to 400
401 to 1750
±(0.2% of span + 6)
±(0.1% of span +3)
E -160 to 990 ±(0.1% of span + 1)
N -170 to 50
51 to 1290
±(0.1% of span + 3)
±(0.1% of span + 1)
Programmable voltage measurement ranges per channel: ±10 mV, ±25 mV, ±50 mV, ±100 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, ±25 V, ±50 V
Voltage measurement accuracy:
At 25 °C ambient temperature.
Following 30 minutes warm-up.
Excluding common mode error.
±(0.05% of range + 10 µV)
Input impedance: 1 MΩ, all ranges
Absolute maximum input without damage: 120 V (±dc or rms)
Maximum common mode voltage: 120 V (±dc or rms)
Min common mode rejection (330Ω unbalance): >110 dB (DC to 60 Hz)
Channel-to-channel crosstalk rejection: (Rsource ≤ 330 Ω; Freqsource ≤ 60 Hz) > 110 dB
Alarm and trigger hysteresis: Voltage: ±0.5% of the full scale range
Temperature: ±0.3 °C
Digital/Pulse Inputs
Number of Channels: 4
Pull-up value: 4.7 KΩ
Isolation: None
Input high voltage threshold: 1.8 V minimum
Input low voltage threshold: 1.4 V maximum
Absolute voltage input without damage: 0 ≤ V ≤ 30 V
Maximum count value: 232 - 1 (.csv format)
65,535 (WinDaq format)
Maximum measured frequency: >100 kHz (.csv format)
65,565 Hz (WinDaq format)
Alarm Outputs
Number of channels: 4
Maximum drain voltage: 30 V
Maximum sink current: 100 mA
ADC Characteristics
Voltage Measurement Resolution:
Range Resolution
±10 mV 305 nV
±25 mV 763 nV
±50 mV 1.52 µV
±100 mV 305 µV
±250 mV 763 µV
±500 mV 15.3 µV
±1 V 30.5 µV
±2.5 V 76.3 µV
±5 V 152.6 µV
±10 V 305 µV
±25 V 763 µV
±50 V 1.53 mV
Thermocouple Temperature Measurement Resolution:
TC Type Resolution
J 0.086 °C
K 0.096 °C
T 0.037 °C
B 0.096 °C
R/S 0.111 °C
E 0.073 °C
N 0.092 °C
4-20 mA current loop resolution: 26,214 ADC counts over the 4-20 mA range (±5 VFS range with 250-Ω shunt resistor)
Programmable sampling intervals: 25, 50, 100, 250, 500 mS
1, 2, 5, 10, 20, 30 S
1, 2, 5, 10, 20, 30 minutes
1 hour, External
Internal Memory
Type: Non-volatile flash
Size: 4 GB (standard); 32 GB (optional)
Use: Automatic backup of recorded data
Indicators and Controls
Signal I/O: Dual, removable 16-position screw terminal connectors
Power connector: 2.0 mm center pin, 5 mm shell
Status light: One multicolor LED indicating status
Alarm lights: 4 multicolor LEDs
Ethernet interface connector: RJ45
USB drive receptacle: Type A male
USB connector: Mini B style (usage is reserved)
Control button: Push type to set device operating mode
Ground: Screw terminal to establish Earth ground.
Power I/O
Input power requirements: 9-36 V dc @ 7.5 Watts
9-36 V dc @ 10 Watts (w/excitation)
Excitation power supply output: 15 V, 130 mA max, 13 mA min
Environmental
Operating Temperature: 0 to 70 °C (32 to 158°F)
Storage Temperature: -20 to 70 °C (-4 to 158°F)
Storage Humidity: 0 to 90% non-condensing
Physical Characteristics
Enclosure: All-metal. Steel top, aluminum base
Mounting: Desktop; bulkhead with optional brackets
Dimensions: 5.4375 D × 4.125 W × 1.5 H inches
13.81D × 10.48W × 3.81H cm
Weight: <1lb. (453 grams)
Configurable Components
Network variables: IP address, Subnet mask, Gateway, DNS
Account log-on information: For FTP, SFTP, SMB, SMTP
User log-on information: User and administrator names and passwords
Supported Standards
Network Time Protocol (NTP): Syncs internal time and date clock to Internet time
File Transfer Protocol (FTP): Allows the instrument to push re-corded data to an FTP server
Secured File Transfer Protocol (SFTP): Allows the instrument to push re-corded data to an SFTP server
Server Message Block (SMB) protocol: Allows the instrument to record data to a local server drive
Simple Mail Transfer Protocol (SMTP): Allows the instrument to send data and alarms to multiple email addresses
Display Subsystem
Digital display: Numeric display of acquired values scaled into engineering units in real time. Selectable precision of 1 to four digits to the right of the decimal point.
Waveform display: Scrolling plot of selected channel data in real time versus time of day.
Alarms status: Virtual LEDs display the status of the four alarm outputs
Channel Settings Subsystem
Analog channel configuration: Voltage and measurement range, temperature and thermocouple type, moving average filter, engineering units, channel label
Digital/pulse channels: Discrete, count, count with reset, frequency, engineering units, chan-nel label
Trigger Subsystem
Start or stop recording trigger conditions: Level: Above/below level, In/out window
Alarm: Upon alarm activation
Date/time: Specific date and time. Daily selection
External
Auto rearm: Enabled or disabled
Alarm Subsystem
Level or edge selection: Level: Alarm is activated when alarm condition is met on first encounter
Edge: Alarm is activated only after first not being met.
Analog/pulse channel levels: Above/below level, In/out window
Thermocouple burnout: Any burnout detected on a Thermocouple channel
Selectable alarm ports: 1-4
Alarm hold: Enable/disable
File Subsystem
File browse/download: Browse files on the DI-808 internal flash memory or connected USB drive and allow selectable down-loads to the client device.
Format local file storage: Formats internal flash memory, erasing previously recorded files and reallocating file space for new recorded data.
Get local file space: Returns the available file space.
Base file name: Allows recorded files to be assigned a definable file name, and to option-ally have date and time appended.
File type: Allows the recorded file format to be defined as either ASCII CSV or binary WDH.
Device Subsystem
Device settings and information: Program device sampling interval, temperature units (°F/°C), enable or disable auto start on boot feature, time/date/ synched to connected PC or NTP server, reboot device.
Network configuration: Configure device IP address, DNS, Subnet mask, Gateway.
Users and accounts: Configure user and administrator names and passwords.

Videos

See the PUREC in action
PU[REC]

Get your fist look into the PU[REC] Data Acquisition System.

Similar Products

Reviews