Model DI-4718BX
Measure Anything with this 16-channel dual-core USB & Ethernet Data Logger and Data Acquisition System for DI-8B Amplifiers. Expandable to 128 channels
Stock
- Includes a dual-core DI-4718BX instrument, a 5-foot Ethernet cable, a 6-foot USB cable, a power supply and adapter, a 4 pin screw terminal for remote control/events, a USB thumb drive with WinDaq software, an NIST-traceable calibration certificate (pdf included on thumb drive), a screwdriver for signal connections. DI-8B amplifiers sold separately.
- Measures temperature, pressure, flow, current, voltage, and more using isolated 8B amplifiers. At least one 8B module is required. View the DI-8B amplifier selection guide
- ExcelLink Add-on included
- WinDaq UtilityPack Add-on included
- USB & Ethernet Data Acquisition System
- Easy signal swapping connectors
- Up to 160,000 Hz Sample Throughput Rate per core using WinDaq Acquisition software
- Sixteen DI-8B signal-conditioned analog inputs
- 12 to 16-bit analog-to-digital resolution (Calculate Resolution)
- Adaptable low-pass filter per channel
- Corner frequency set as a function of sampling rate
- PC-connected operation only
- Included ChannelStretch™ supports multi-unit synchronization expansion:
- Up to sixteen instruments
- Up to 480 kHz throughput
- Up to 128 analog channels and 112 digital ports
- Syncs with itself and models DI-4108, DI-4208, DI-4718B, and DI-4730 in any combination using the same communications interface. ChannelStretch™ is included with the DI-4718BX, other hardware models require an unlock code per instrument.
- Two digital inputs for WinDaq Remote Events and Remote Start/Stop
- Stack with the DI-4730 - combine the high-performance capabilities of the DI-4370 with the signal-conditioned channels of the DI-4718BX
- Software support includes ready-to-run WinDaq software and documented protocol for software development in all operating systems (visit our GitHub repository for example programs)
- 10% Education Discount
Description
DI-4718BX USB & Ethernet Data Logger and Data Acquisition System is a dual-core system based on DI-4718B for applications that require signal conditioning. It packs two popular DI-4718s inside the enclosure for easy stackable mounting configuration with DI-4730. Install up to sixteen DI-8B isolated signal conditioning modules on the printed circuit board using the removable front panel. Each DI-8B module protects, filters, amplifies, and isolates an input signal, providing an advanced signal conditioning solution for nearly any industrial measurement.
DI-4718BX features 12- to 16-bit analog-to-digital resolution as a function of sample rate. Lower sampling rates deliver higher resolution readings. The maximum analog sampling throughput rate of the DI-4718BX analog subsystem is 160 kHz per core, providing 12 bits of resolution. Resolution varies with respect to sample rate. Add up to 128 analog channels with ChannelStretch™ channel expansion, which is supported in all USB and Ethernet versions. Synchronize any USB DI-4718Bs, DI-4108s, DI-4208s, and/or DI-4730s to one PC. Acquire from as many as 128 analog and 112 digital channels at combined total throughput rates over 480 kHz.
The included WinDaq data acquisition software makes configuring the DI-4718BX for PC-connected operation quick and intuitive. Use WinDaq to set up channels and create a reference file.
Accessories

Description
DI-8B amplifiers offer the convenience to mix and match modules based upon measurement function and range to meet any application requirement, from the most simple to the most complex.

Description
4-20mA Output High precision pressure sensor measures PSI ranges of -14.5 to 14500 PSI dependant on model. 8 or 12-30V supply voltagle, such as 101086 AC/DC 12V output adapter or a car battery. Made with 316 stainless steel and high temperature auto-graded plastic. 0.25-0.5% accuracy. 4-20mA linear current output. 10% Educational Discount

Description
Spare power supply for DI-808, DI-4718B, DI-4178BX, and DI-4730 products.

Description
Stainless steel handle for stacking brackets SB-1 and SB-1000.

Description
Pair of right-angle mounting brackets (with mounting screws) for DI-47xx and DI-7x0 Series instruments.

Description
Pair of stacking brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, and DI-808 Series instruments

Description
Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

Description
Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

Description
Replacement 4-pin removable screw terminal block for Remote Control block receptacle for DI-4718BX.

Description
DC power connector for powering the DI-808 or DI-4718B from a source other than the provided ac adaptor.

Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for all DI-4718BX data acquisition and data logger products. Includes both before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DI-4718BX purchase. Installs drivers and WinDaq recording and playback software. ChannelStretch included for DI-4718BX.

WinDaq ExcelLink
WinDaq-to-Excel Real Time Link
High speed (up to 160K s/s) with powerful trigger methods to capture or stream data to Excel in real time, compatible with ChannelStretch, supports both 32- and 64-bit Excel. No programming is needed.

WinDaq Playback Web Viewer
Cross-platform Web Browser-based Waveform Playback Viewer to analyze your recorded WinDaq or Graphtec data over iPad, macOS, Windows, Android or Linux system

WinDaq Cloud Link and UtilityPack
Tools
WinDaq UtilityPack enhances WinDaq acquisition software with powerful tools such as Cloud Link, live FFT, Spectrogram, Meter, Gauge, and Smart Digital Outputs, all of which can launch automatically when WinDaq starts.

WinDaq XY Viewers
Live XY charting for WinDaq and WWB
Originally designed for GE Mining Division, these two XY plotting utilities are great tools for trouble shooting their mining equipments.

Specifications
| Analog Inputs | |
| Number of Channels: | 16 configured for signal conditioned inputs |
| Channel Configuration: | Defined by DI-8B Module |
| Measurement Range: | Defined by DI-8B Module |
| Accuracy: | ±0.25% FSR + 8B module + CJC error @25°C, 10Hz sample rate, digital filter on |
| Input Impedance: | Defined by DI-8B Module |
| Input offset voltage: | Defined by DI-8B Module |
| Channel-to-channel crosstalk rejection: | -75db @ 100Ω unbalance |
| Offset temperature coefficient: | 0.25µV/°C |
| Digital filtering: | Conditional over-sampling |
| CJC Error: | 1.5°C plus 8B Module |
| Isolation (via DI-8B Modules) | |
| Input-to-Output: | 1000VDC/Peak AC |
| Channel-to-Channel: | 500VDC/Peak AC |
| Digital Inputs | |
| Ports: | D0: WinDaq Remote Events D1: WinDaq Remote Start/Stop |
| Threshold Levels: | TTL-compatible |
| Max applied Voltage: | 25 V DC |
| A/D Characteristics | |
| Type: | Successive approximation |
| Resolution: | 12 to 16-bit (Calculate) |
| Minimum Conversion Time: | 69.4µs |
| Scanning Characteristics | |
| Max. throughput sample rate: | Standard: 160 kHz per core |
| Min. throughput sample rate: | Standard: 20 Hz (2.2 samples per hour with WinDaq) |
| Sample Rate Timing Accuracy: | 100 ppm |
| Max. scan list size: | 17 |
| Calibration | |
| Calibration cycle: | One year |
| Ethernet Interface | |
| Type: | 10/100Base-T |
| Connector: | RJ-45 |
| Protocol: | UDP/IP |
| Server Type: | DHCP or Fixed IP |
| Rear Panel Indicators, Connections, and Controls | |
| Button: | Multi-function control |
| USB A Connector: | Downstream USB port for expansion |
| Ground Lug: | Terminal for Ground |
| Status LED | One multicolor LED for status indication |
| Power Connector: | 9 to 36 VDC, 10 watts + 8B modules |
| Ethernet Connector: | RJ-45 |
| Front Panel Connections | |
| Input connectors: | Four removable sixteen position terminal blocks, 28 AWG min, 16 AWG max |
| Radio Jack: | Standard 3.5 mm for remote control signals |
| USB ChannelStretch™ Operation | |
| Total Max Units: | 16 |
| Max Channel Count: | 128 Analog, 112 Digital |
| Max Throughput: | ≥480 kHz (higher speeds may result in data loss) |
| Synchronization Conditions: | Syncs with any combination of DI-4718BX, DI-4718B, DI-4730, DI-4108, and DI-4208 Ethernet instruments. All synced instruments must operate at the same sample rate per channel, regardless of channel number, type, or range. All instruments must be connected to the same USB controller. The use of USB hubs are recommended to meet this requirement. ChannelStretch is included with the DI-4718BX, but must be purchased separately with other hardware types. |
| Ethernet ChannelStretch™ Operation | |
| Total Max Units: | 16 |
| Max Channel Count: | 128 Analog, 112 Digital |
| Max Throughput: | ≥50 kHz (higher speeds may result in data loss) |
| Synchronization Conditions: | Syncs with any combination of DI-4718BX, DI-4718B, DI-4730, DI-4108, and DI-4208 Ethernet instruments. For most accurate synchronization, all instruments should be connected to the same Ethernet switch. ChannelStretch is included with the DI-4718BX, but must be purchased separately with other hardware types. |
| Power | |
| Power Consumption: | 4W + 8B Modules, max 20W |
| Environmental | |
| Operating Temperature: | 0°C to 50°C |
| Operating Humidity: | 0 to 90% RH non-condensing |
| Storage Temperature: | -20°C to 60°C |
| Storage Humidity: | 0 to 90% RH non-condensing |
| Physical Characteristics | |
| Enclosure: | Aluminum base with steel wrap-around. |
| Mounting: | Desktop; Bulkhead |
| Dimensions: | 7.29W × 9L × 1.52H in. (18.52W × 22.86L × 3.86H cm.) |
| Weight: | 2 lbs. 3.8 oz. (35.8 oz) + DI-8B modules |
| Power Requirements: | 9 to 36 VDC, 10 watts + 8B modules |
| Software Support | |
| WinDaq software: | View Supported Operating Systems at https://www.dataq. com/products/windaq/windows-compatibility/ |
| Programming: | Instrument protocol, ActiveX Control |
Articles
Frequency and True RMS Data Acquisition
Intelligent Oversampling Methods Extend Measurement Flexibility
Strain Gage-Based Transducer and Amplifier Selection and Calibration
How To Connect and Calibrate Thermocouples Using DI-8B47 Series Amplifiers
Connection and Calibration of Strain-Gage Based Transducers Using DI-8B38 Series Amplifiers
How To Choose Strain Gage-based Transducers for PC-based Data Acquisition Applications
Videos
Downloading Data via Ethernet
How to Download Data From Your DI-4000 Series Instrument Via Ethernet.
Synchronous Data Acquisition
Sync up to 16 DI-2108-P or 4000 Series units together and record to a single file.
Similar Products
Quick Product Comparison
| Model | Analog channels |
Expandable* | Measurement Range† |
Thermocouple Support |
Max Sample Rate (Hz) |
ADC Resolution |
Digital I/O |
Interface | Data Storage |
| DI-4718B | 8 | Yes | A | Yes (DI-8B) | 160,000 | 12 to 16 | 2 In | USB, Ethernet | PC or USB flash |
| GL260 | 10 | - | B | Yes | 100 | 16 | 4 In 4 Out | USB | PC, USB flash, Internal, Cloud |
| GL860 | 20 | Yes | B | Yes | 100 | 16 | 4 In 4 Out | USB, Ethernet | PC, USB flash, Internal, Cloud |
| DI-4108 | 8 | Yes | C | No | 160,000 | 12 to 16 | 7 Bi | USB, Ethernet | PC or USB flash |
| DI-4208 | 8 | Yes | D | No | 160,000 | 12 to 16 | 7 Bi | USB, Ethernet | PC or USB flash |
*Expansion capabilities dependent on model.
†Use the following chart to determine Measurement Ranges:
| A | B | C | D |
| Defined by DI-8B module |
±20 mV ±50 mV ±100 mV ±200 mV ±500 mV ±1 V ±2 V ±5 V ±10 V ±20 V ±50 V ±100 V 1-5 V Thermocouple More (dependent on accessories) |
±200 mV ±500 mV ±1 V ±2 V ±5 V ±10 V |
±2 V ±5 V ±10 V ±20 V ±50 V ±100 V |


View Cart