USB Data Acquisition Starter Kit
|
Data Logger System for DI-8B ModulesDI-718B Data Logger products operate Stand-alone or PC-connected
Product Highlights Product Highlights
The DI-718B is an eight-channel, DI-8B module data logger system. Each DI-718B accepts up to eight high-performance, plug-in (DI-8B) signal conditioning modules to include virtually any isolated, industrial-type signal. Because DI-8B modules are identical in pinout and size, they can be mixed or matched in any combination. Choose from thermocouple, true rms, voltage, strain, frequency, process current, RTD, potentiometric, or DC transducer—whatever suits your application. A eraseable sticker on the top of the instrument allows easy identification of all installed DI-8B modules. DI-718B Series options include interface type and PC-connected or stand-alone data logger operation. Interface options are USB or Ethernet. Instruments with the stand-alone data logger option feature a built-in multimedia socket that accepts standard Secure Digital (SD) memories to which acquired data may be stored without a connected PC. SD memories are the same commonly available mass storage devices used with digital cameras and MP3 players. Memories ranging in size from 16MB to 2GB are supported. Instruments without this option must remain tethered to a PC’s USB or Ethernet port during data acquisition and use the PC’s own program and memory to store acquired data. Make Industrial Measurements Through DI-8B Plug-in Signal Conditioning ModulesEach channel on the DI-718B accomodates one DI-8B module providing a single channel of isolated input protection, amplification, and filtering. DI-8B modules are plugged into a socketed backplane and are secured with a mounting screw. Each DI-718B channel has 4 corresponding screw terminals for your signal connections: channel +, channel-, excitation +, and excitation -. These terminals satisfy all transducer inputs and provide sensor excitation if necessary. Access to the DI-8B modules is through a removable front panel. Powerful Data Acquisition Server CapabilityDI-718B Stand-alone data loggers are the first in their price range to offer data acquisition server capability. Acting as a server allows stand-alone instruments to locally and independently acquire data to their memory cards, and then make that acquired data available upon demand, either by plugging the memory card into a reader, or uploading via the Ethernet interface. Ethernet-enabled DI-718Bs provide the most power and flexibility. A DI-718B with an Ethernet interface and built-in memory transparently becomes like any other computer on a network, able to share recorded data over a network to a PC on the other side of the facility, or over the Internet to a PC on the other side of the world. These stand-alone instruments can be added easily and seamlessly to existing networks without incremental bandwidth burdens, storing data in memory and uploading on demand. Stand-alone data loggers can also be controlled locally using multifunction push-button control and multi-colored, red, green, orange LED status indicator. To learn more about the DI-718B's powerful stand-alone capabilities, click here. Recommended Memory CardFor optimal performance, DATAQ Instruments, Inc. recommends using a Lexar Professional 133X 2 Gigabyte Secure Digital Flash Memory Card to record your data. Memory cards are available through our online store. Fast Throughput RateSupports sample throughput rates to 14400 samples per second (assumes SD latencies of 80 milliseconds or less) to SD with stand-alone Models and 4800 samples per second to PC with PC-connected Models. WinDaq/HS is required to achieve recording rates over 1,108 Hz with PC-connected instruments. Easy to Connect & UseInstalls in seconds. Simply connect to your computer's USB port or an Ethernet port using the supplied cable. Connect power, then connect your signals to the provided screw terminal blocks. Stand-alone models just need a memory card and power. Includes WinDaq SoftwareBe up and running minutes out of the box with WinDaq acquisition and playback software. WinDaq/Lite software is included free with the purchase of every DI-718B instrument. WinDaq/Lite operates at a maximum throughput recording rate of 1,108 Hz with a DI-718B Instrument. A special version of WinDaq acquisition software may be purchased (WinDaq High Speed Option) allowing you to record data at the speed of the instrument (up to 4800 Hz). WinDaq Waveform Browser, our unrestricted playback and analysis software for Windows, is also included free with the purchase of every DI-718B. Use it to review, measure, compare, and analyze the waveform file after it has been recorded by WinDaq acquisition software. WinDaq software products support up to 14 bits of measurement resolution. Looking for the same features without signal conditioned inputs?Our DI-710 Series Data Logger provides all the same great features as the DI-718B Series - without the built-in DI-8B backplane. View our complete line of Data Loggers. Special Discount Bundle OfferCheck out the special bonus bundle offers. Save money when you buy the DI-718B model with WinDaq/XL and WinDaq/HS. Special stand-alone bundle provides an SD Card and a card reader. Click here for more information. Ordering Information, Models, and Prices
Note: Pricing outside the U.S. will be higher to account for shipping, taxes, duty, currency fluctuation, local warranty and technical support in your country. DI-8B modules are NOT included with the purchase of ANY DI-718B instrument and must be ordered individually. DI-718B Data Logger Software and Accessories
Note: Pricing outside the U.S. will be higher to account for shipping, taxes, duty, currency fluctuation, local warranty and technical support in your country. DI-8B modules are NOT included with the purchase of ANY DI-718B instrument and must be ordered individually.
Knowledge Base and Common Support IssuesEthernet Installation to DHCP network Ethernet Installation to Static IP network Ethernet Installation Directly-connected (one DI-71x to one PC) Connection and Calibration of Strain-Gage Based Transducers Using DI-8B38 Series Amplifiers How to Export Recorded Data to Excel How To Choose Strain Gage-based Transducers for PC-based Data Acquisition Applications Strain Gage-Based Transducer and Amplifier Selection and Calibration Frequency and True RMS Data Acquisition Learn the Importance of Isolation In Four Easy Lessons Intelligent Oversampling Methods Extend Measurement Flexibility Support Forum
Data Acquisition Product Links(click on text to jump to page) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||