Site Search:

Model EL-USB-1

Single Channel Data Logger Measures Temperatures from -30°C to +80°C (-31°F to +176°F)

$74.99
In
Stock
  • Includes an EL-USB-1 data logger, a battery (pre-installed), and downloadable software (CALIBRATION CERTIFICATE sold separately under ACCESSORIES and must be ordered at time of purchase)
  • -35 to +80°C (-31 to +176°F) measurement range
  • USB Interface for Set-up and Data Download
  • 2 User-Programmable Alarm Thresholds
  • Bright Red, Green and Orange LED Indication
  • Replaceable Internal Lithium Battery
  • IP 67 Protection (totally protected against dust; protected against liquid immersion up to 1m)
  • Quantity Discount
Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
EL-USB-1 Data Logger
This data logger has one degree of resolution.This data logger has a single channel.This device measures -30 to +80°C (-31 to +176°F).This data logger measures temperature.This data logger can record one sample every 10 seconds.
This data logger has a USB interface.This data logger records data to internal memory.Get same day shipping when you order this data logger before 3PM ETThis data acquisition system has a 30-day Money back guaranteeUse coupon code EL10USB for 10% off your Lascar data logger purchase.

Description

The EL-USB-1 temperature data logger measures and stores up to 16,382 temperature readings over a -35 to +80°C (-31 to +176°F) range. Easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC’s USB port and running the purpose-designed software that allows you to easily graph, print and export data to other applications. The EL-USB-1 data logger is supplied with a long-life lithium battery which can typically allow logging for more than 1 year. Function and alarm states are indicated by flashing red, green and orange LEDs. The data logger is protected against moisture to IP67 standard when the protective cap is fitted.

Accessories

BAT 3V6

3.6V Battery

$5.99
Lascar Data Logger Battery

Description

Replacement 3.6V, 1200mAh lithium battery. Please Note: Continental U.S. shipping ONLY.

EL-USB Case

Waterproof Case

$26.99
EL-USB Case

Description

Metal, waterproof case for EL-USB-1, EL-USB-2, and EL-USB-2+ data loggers (this case does NOT fit the EL-USB-2-LCD). Please Note: Humidity measurements are not possible when using this case. View Dimensions.

CAL EL-USB-TEMP-1

Calibration Certificate (1st Cal Value)

$40.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase this first point option first for each device, and then additional points per device as required. Standard points are $40. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

CAL EL-USB-TEMP-2

Calibration Certificate (2nd Cal Value)

$25.00

Select Temperature Point:

Temperature Calibration Certificate

Description

Before purchasing please read the blog post EL-USB Data Logger Series and Calibration Certificates. NIST traceable calibration certificate (first point) in compliance with ISO10012-1, ISO 17025, and MIL-STD-45662A. Purchase the first point option first (CAL EL-USB-TEMP-1) for each device, and then additional points per device as required. Standard points are $25. Custom points may be specified and entered into the special instructions section of our online store and incur an additional charge.
Please Note: Calibration certificates cannot be returned for a refund. These calibration certificates have a typical lead time of 3-4 weeks.

Software

EasyLog Software

Configuration Software

FREE Configuration and download software for Lascar Data Loggers.

Lascar EasyLog Software

Specifications

Number of Channels: One
Measurement Range: -35 to +80°C (-31 to +176°F)
Internal Resolution: 0.5°
Accuracy (overall error): ±1°C (±2°F)
Logging Rate: 1 sample every 10 seconds
1 sample every minute
1 sample every 5 minutes
1 sample every 30 minutes
1 sample every hour
1 sample every 6 hours
1 sample every 12 hours
Memory Capacity: 16,382 samples
Operating Temperature Range: -35 to +80°C (-31 to +176°F)
Battery Life 1 year (@ 25 °C and 1m logging interval)

Videos

Introducing the EL-USB-1 Data Logger
Introducing the EL-USB-1

Introducing the EL-USB-1 Low-cost USB Temperature data logger.
EasyLog Software
EasyLog Setup

Learn how to set up Lascar Data Loggers with EasyLog Software.
EL-DataPad Setup
EL-DataPad Setup

Learn how to set up and configure your EL-USB data logger with the Optional EL-DataPad.

Reviews