Model DI-8B47K-05
Isolated 0°C to +500°C (+32°F to +932°F) 8B-style Amplifier

- Measures 0°C to +500°C (+32°F to +932°F)
- Interfaces to Thermocouple Type K
- ±1.05°C Accuracy
- Linearizes Thermocouple Signal
- High Level Voltage Outputs
- 1500Vrms Transformer Isolation
- ANSI/IEEE C37.90.1
- Input Protected to 240VAC Continuous
- 120dB CMR
- 70dB NMR at 60Hz
- Low Drift with Ambient Temperature
- Accurate CJC -40°C to +85°C
- CSA, FM, and CE Certifications Pending
- Mix and Match Modules
- View Dimensions and pinout
- Documentation
- Applications
- Multimedia
- Support
None Available

2-position analog I/O backplane, non-multiplexed. For use with DI-8B Modules. View the 8BP02 schematic or the 8BPxx schematic or download the pdf.

4 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP04 schematic or the 8BPxx schematic or download the pdf.

8 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP08 schematic or the 8BPxx schematic or download the pdf.

16 channel backplane. Each module has its own analog bus. For use with DI-8B Modules. View the 8BP16 schematic or the 8BPxx schematic or download the pdf.
- 8 analog inputs
- 4800 Hz max sample rate
- Any industrial measurement
- Uses isolated 8B amplifier modules
- Small form factor fits into tight spaces
- Wide power supply range (9-36 Vdc)
- Includes WinDaq software
$795
- 8 analog inputs
- 14.4 kHz max sample rate
- Any industrial measurement
- Uses isolated 8B amplifier modules
- Records to PC or SD memory
- Small form factor fits into tight spaces
- Includes WinDaq software
$895
- 8 analog inputs
- 4800 Hz max sample rate
- Uses isolated 8B amplifier modules
- Makes any industrial measurement
- Small form factor fits into tight spaces
- Wide power supply range (9-36 Vdc)
- Includes WinDaq software
$595
- 8 analog inputs
- Up to 14.4 kHz max sample rate
- Any industrial measurement
- Uses isolated 8B amplifier modules
- Records to PC or SD memory
- Small form factor fits into tight spaces
- Includes WinDaq software
$695
- 16 analog inputs
- 4800 Hz max sample rate
- Any industrial measurement
- Uses isolated 8B amplifier modules
- Includes WinDaq software
- Wide power supply range (9-36 Vdc)
- Provided with ActiveX Control set
$1395
- 16 analog inputs
- 14.4 kHz max sample rate
- Any industrial measurement
- Uses isolated 8B amplifier modules
- Records to PC or SD memory
- Includes WinDaq software
- Wide power supply range (9-36 Vdc)
$1495
- 32 isolated analog channels
- Any industrial measurement
- 150 kHz max sample rate
- Uses isolated 8B amplifier modules
- Supports distributed synchronized operation
$3995
- 0°C (32°F) to 760°C (1400°F)
- J-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- -100°C (-148°F) to 300°C (572°F)
- J-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- 0°C (32°F) to 500°C (932°F)
- J-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- -100°C (-148°F) to 760°C (1400°F)
- J-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- 0°C (32°F) to 1000°C (1832°F)
- K-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- -100°C (-148°F) to 1350°C (2462°F)
- K-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- 0°C (32°F) to 1200°C (2192°F)
- K-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- -100°C (-148°F) to 400°C (752°F)
- T-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00
- 0°C (32°F) to 200°C (392°F)
- T-type thermocouples
- 3 Hz bandwidth
- Passes DC to 3 Hz signals
- Fully isolated
$132.00